http://www.spinachbase.org/https://duniapermainan.id/https://borobudur.site/https://beritamakan.xyz/http://lesfergusonjr.com/https://www.drafthorsejournal.net/https://ajudanze.us/https://soykb.org/https://www.laoplazahotel.com/https://bidpropamkaltara.com/https://www.inmercociudades.org/https://hanomantoto.vip/https://togeljackpot.bio/https://wsf2024nepal.org/https://www.ha-software.com/https://www.demo.mimikakab.go.id/https://alapp.selumakab.go.id/main/https://www.aveironet.com/https://motocofservice.com/https://missglobalnigeria.com/https://gilchristfliegen.com/https://cosmictoto.id/https://alapp.selumakab.go.id/log/https://borobudurbet-com.net/https://auroratotosatu.net/https://auroratoto-2.com/https://totocosmic.net/
Non-fluorocarbon Series Standard type Lateral mounting

Non-fluorocarbon Series Standard type Lateral mounting

Non-fluorocarbon Series Standard type Lateral mounting

Non-fluorocarbon Series Standard type Lateral mounting

Saves maintenance and disposal costs.
Rich lineup in lateral mounting type.

COOLCABI ノンフロンシリーズ

 

Features

Type of mounting Environment Cooling method Functions Obligatory inspection by Japanese law
Lateral/Rececced Duct kit (Option) Adjustable louver (Accessory) Indoor Compressor Energy-saving mode Display N/A

 

Certificates/Approvals

EU RoHS2 China RoHS CE UL CSA PSE

 

 

Model/Specification

Model OCA-H300BC-A200 OCA-H600BC-A200 OCA-H1000BC-A200 OCA-H1600BC-A200 OCA-H2200BC-A200 OCA-H2900BC-A200
Type of mounting Lateral mounting
Cooling capacity *1 250/300W 500/610W 800/1000W 1450/1600W 2000/2200W 2600/2900W
Rated volage(50/60Hz) Single phase 200VAC Three phase 200VAC
Current consumption *2 Rated 1.4/1.3A 2.1/2.1A 3.3/3.1A 3.9/4.1A 3.3/3.4A 4.7/5.0A
Max. 1.6/1.5A 2.5/2.6A 3.7/3.7A 4.6/5.0A 3.8/4.1A 5.6/6.3A
Starting current 3.7/3.6A 6.8/6.1A 13.4/11.6A 15.6/14.5A 14.3/15.6A 18.5/19.5A
Power consumption *2 Rated 250/260W 400/410W 570/610W 730/810W 910/1050W 1340/1530W
Max. 280/290W 480/520W 670/720W 880/990W 1100/1280W 1650/1990W
Comp. motor output 100W 275W 375W 525W 850W 1300W
Working temperature *3 +20 to +50℃
Working humidity Not exceeding 85%RH, free from condensation
Noise(Charactristic A) 65dB(A) 65dB(A) 65dB(A) 68dB(A) 69dB(A) 70dB(A)
Temp. setting range*3 +30 to +45℃ (Initial setting:+35℃)
Display Innter temperature/Alarm code/Operation lamp/Alarm lamp
Function Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection,
Maintenance reminder, Forced cooling operation for inspection
External output Alarm output 1a 240V 1.5A×2(COMMON)
Vibration withstand Vibration frequency10 to 55Hz, Amplitude 0.15mm, Sweep cycle 10 times
Protection category *4 Internal circuit IP54 equivalent
Conformity to standards EMC Directive EN61000-6-2, EN61000-6-4 complaint
LV directive EN60335-1, EN60335-2-40, EN62233
Environment RoHS2
Refrigerant R1234yf
(130g)
R1234yf
(200g)
R1234yf
(500g)
R1234yf
(700g)
R1234yf
(940g)
R1234yf
(1700g)
GWP *5 <1
Color Powder coating N8 corresponding, N4 corresponding
Dimensions(mm) W300×H500
×D150
W300×H550
×D200
W350×H900
×D200
W390×H950
×D220
W450×H1150
×D220
W450×H1350
×D220
Weight 16.0kg 18.0kg 31.0kg 37.0kg 51.0kg 60.0kg
*1 Nominal value when both of internal and external temperatures are +35℃. By attaching the provided louver, the capacity reduces by up to 5%.
*2 Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max”.
*3 Use only within the specified temperature range.
*4 Excl. drain pipe
*5 By IPCC 5th Report 2013

 


Product lineup

OCA-H300BC-A200

OCA-H300BC-A200

 

Cooling capacity

250/300W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc. ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs
●Nut:4 pcs ●Packing:1 roll ●Drain hose:1 pc (2m) ●Terminal board:1 pc.
●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy
●Adjustable louver:1 pc.●Screws for louver:4 pcs

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-300BCIN-200V CF-S1(2pcs/set)
External fan model FM-300BCOUT-200V

Performance diagram

Performance diagram

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

Mounting view

取付図

 

 

OCA-H600BC-A200

OCA-H600BC-A200

 

Cooling capacity

500/610W(50/60Hz)

A complete set of supply

●COOLCABI:1pc ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs
●Nut:4 pcs ●Packing:1 roll ●Drain hose:1 pc.(2m) ●Terminal board:1 pc.
●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy 
●Adjustable louver:1 pc. ●Screws for louver:4 pcs

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-600BCIN-200V CF-S1(2pcs/set)
External fan model FM-600BCOUT-200V

Performance diagram

能力グラフ

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

Mounting view

取付図

 

 


 

 

OCA-H1000BC-A200

OCA-H1000BC-A200

 

Cooling capacity

800/1000W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc. ●Fixing bolt:6pcs ●Washer:6 pcs ●Spring washer:6 pcs 
●Nut:6 pcs ●Packing:1 roll ●Drain hose:1 pc.(2m) ●Terminal board:1 pc. 
●Alarm explanation sheet:1 sheet ●Insutruction manual:1 copy 
●Adjustable louver:2 pcs ●Screws for louver:8 pcs

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-1000BCIN-200V CF-S2(2pcs/set)
External fan model FM-1000BCOUT-200V

Performance diagram

能力グラフ

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

Mounting view

取付図

 


 

OCA-H1600BC-A200

OCA-H1600BC-A200

 

Cooling capacity

1450/1600W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc ●Fixing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs 
●Nut:6 pcs ●Packing:1 roll ●Drain hose:1 pc.(2m) ●Terminal board:1 pc. 
●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy 
●Adjustable louver:2 pcs ●Screws for louver:8 pcs

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-1600BCIN-200V CF-S3(2 pcs/set)
External fan model FM-1600BCOUT-200V

Performance diagram

能力グラフ

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

Mounting view

取付図

 


 

OCA-H2200BC-A200

OCA-H2200BC-A200

 

Cooling capacity

2000/2200W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc ●Fixing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs 
●Nut:6 pcs ●Packing:1 roll ●Drain hose:1 pc.(2m) ●Terminal board:1 pc. 
●Alarm explanation sheet:1 sheet  ●Instruction manual:1 copy
●Adjustable louver:2 pcs ●Screws for louver:8 pcs

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-2200BCIN-200V CF-S7(2 pcs/set)
External fan model FM-2200BCOUT-200V

Performance diagram

能力グラフ

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

Mounting view

Mounting view

 


 

OCA-H2900BC-A200

OCA-H2900BC-A200

 

Cooling capacity

2600/2900W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc. ●Fixing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs 
●Nut:6 pcs ●Packing:1 roll ●Drain hose:1 pc.(2m) ●Terminal board:1 pc. 
●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy 
●Adjustable louver:2 pcs ●Screws for louver:8 pcs

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-2900BCIN-200V CF-S7(2 pcs/set)
External fan model FM-2900BCOUT-200V

Performance diagram

能力グラフ

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

Mounting view

取付図

 


Option/Related products

Adjustable louver set

 

Cool air is directly blown to the heat source to prevent local temperature rise as well as creating uniform temperature in the enclosure.

Duct kit

 

Use of Duct kit allows cooling from a separately-placed COOLCABI.

Drain evaporator

 

Free from troublesome drain treatment and no more drain worrying about drainage problem.

Self-winding filter

くるくるフィルター

 

Roll filter is wound up automatically by motor.Free yourself from troublesome filter maintenance work.
 

Cautions

・Locate the unit so as to assure good ventilation and distance of at least 200mm from the walls or other units.
・Failure to this may degrade cooling performance of the unit and cause condensation.
・Setting temperature should be basically at 35℃. Avoid setting at an unnecessarily low value.
・Electrical connection should be made via appropriate circuit breakers.
・Do not use this product in the following places.
 - A place where corrosive or flammable gases exist in the air, or where the insulation destruction occurs.
 - A place where the product may be subject to shock or vibration.
・Make sure that electrical wiring work is done by qualified electrician.
・Check for damage on packaging when the product is delivered.
・Any packaging damage can lead to a cause of malfunction. Make sure that there is no damage on the package on delivery and contact your supplier, if any.


Gallery

Non-fluorocarbon Series Standard type Lateral mounting