http://www.spinachbase.org/https://duniapermainan.id/https://borobudur.site/https://beritamakan.xyz/http://lesfergusonjr.com/https://www.drafthorsejournal.net/https://ajudanze.us/https://soykb.org/https://www.laoplazahotel.com/https://bidpropamkaltara.com/https://www.inmercociudades.org/https://hanomantoto.vip/https://togeljackpot.bio/https://wsf2024nepal.org/https://www.ha-software.com/https://www.demo.mimikakab.go.id/https://alapp.selumakab.go.id/main/https://www.aveironet.com/https://motocofservice.com/https://missglobalnigeria.com/https://gilchristfliegen.com/https://cosmictoto.id/https://alapp.selumakab.go.id/log/https://borobudurbet-com.net/https://auroratotosatu.net/https://auroratoto-2.com/https://totocosmic.net/
Standard series Standard type Roof mounting

Standard series Standard type Roof mounting

Standard series Standard type Roof mounting

Standard series Standard type Roof mounting

Rich lineup in roof mounting.

COOLCABI スタンダードシリーズ

 

Features

Type of mounting Environment Cooling method Functions
Duct kit (Option) Adjustable louver (Accessory) Indoor Compressor Energy-saving mode Display


Certificates/Approvals

EU RoHS2 China RoHS CE UL CSA PSE
 

 

 

Model/Specification

Model OCA-S300AC-A100 OCA-S300AC-A200 OCA-S700AC-A200 OCA-S1100AC-A200 OCA-S1700AC-A200 OCA-S2300AC-A200 OCA-S3000AC-A200
Type of mounting Roof mounting
Cooing capacity *1 300/350W 600/700W 950/1100W 1550/1700W 2100/2300W 2700/3000W
Rated voltage(50/60Hz) Single phase 100VAC Single phase 200VAC Three phase 200VAC
Current consumption *2 Rated 2.9/2.6A 1.4/1.2A 2.1/2.1A 3.6/3.7A 4.3/4.4A 3.6/3.9A 5.0/5.6A
Max. 3.3/3.1A 1.5/1.5A 2.4/2.6A 4.3/4.5A 5.3/5.6A 4.3/4.8A 6.2/6.7A
Starting current 7.1/6.6A 3.6/3.4A 6.0/5.9A 12.6/11.9A 14.9/13.8A 14.7/14.5A 17.8/19.2A
Power consumption *2 Rated 245/255W 235/230W 380/410W 660/720W 795/875W 1025/1220W 1405/1735W
Max. 300/305W 275/290W 440/505W 805/900W 1000/1115W 1280/1530W 1825/2110W
Comp. motor output 100W 250W 400W 470W 650W 900W
Working temperature *3 +20 to+50℃
Working humidity Not exceeding 85%RH, free from condensation
Noise(Charactristic A) 61dB(A) 64dB(A) 65dB(A) 66dB(A) 64dB(A) 64dB(A)
Temp. setting range *3 +30 to+45℃ (Initial setting +35℃)
Display Innter temperature/Alarm code/Operation lamp/Alarm lamp
Functions Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection, Maintenance reminder,Forced cooling operation for inspection, Detection of drain overflows, Detection of evaporator ice-up
External output Alarm output 1a 240V 1.5A×2(COMMON)
Vibration withstand Vibration frequency 10 to 150Hz, Acceleration 1.0G, Sweep cycle 20 times
Protection category *4 Internal circuit IP54 equivalent
Conformity to standards EMC Directive EN61000-6-2, EN61000-6-4 complaint
LV directive EN60335-1, EN60335-2-40, EN62233
Environment RoHS2
Refrigerant R134a
(135g)
R134a
(120g)
R134a
(140g)
R407C
(300g)
R407C
(420g)
R407C
(580g)
R407C
(780g)
GWP*5 1430 1770
Color Beige(5Y7/1 corresponding)
Dimensions(mm) W450×H230
×D250
W550×H332
×D270
W600×H350
×D350
W590×H447
×D350
W650×H447
×D400
W760×H447
×D400
Weight 16.0kg 23.5kg 31.5kg 40.0kg 48.0kg 57.0kg
*1 Nominal value when both of internal and external temperatures are +35℃.
*2 Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max”.
*3 Use only within the specified temperature range.
*4 Except drain pipe
*5 By IPCC 5th Report 2013

Product lineup
 

OCA-S300AC-A100/A200

OCA-S300AC-A200

 

Cooling capacity

300/350W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
●Nut:4 pcs ●Drain hose:1 pc(5m) ●L joint:2 pcs ●Terminal board:1 pc
●Packing:1 pc ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

Consumable parts

Replacement fan AC100V AC200V Replacement filter
Internal fan model FM-300ACIN-100V FM-300ACIN-200V CF-S1
(2pcs/set)
External fan model FM-300ACOUT-100V FM-300ACOUT-200V

Performance diagram

OCA-S300AC-A100

能力グラフ

 

OCA-S300AC-A200

能力グラフ

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

 

 

OCA-S700AC-A200

OCA-S700AC-A200

 

Cooling capacity

600/700W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
●Nut:4 pcs ●Drain hose:1 pc(5m) ●L joint:2 pcs ●Terminal board:1 pc 
●Packing:1 pc ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-700ACIN-200V CF-S1(2pcs/set)
External fan model FM-700ACOUT-200V

Performance diagram

能力グラフ

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

 

 

OCA-S1100AC-A200

OCA-S1100AC-A200

 

Cooling capacity

950/1100W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
●Nut:4 pcs ●Drain hose:1 pc(5m) ●L joint:2 pcs ●Terminal board:1 pc
●Packing:1 pc ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-1100ACIN-200V CF-S2(2pcs/set)
External fan model FM-1100ACOUT-200V

Performance diagram

能力グラフ

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

 

 

OCA-S1700AC-A200

OCA-S1700AC-A200

 

Cooling capacity

1550/1700W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
●Nut:4 pcs ●Drain hose:1 pc(5m) ●L joint:2 pcs ●Terminal board:1 pc
●Packing:1 pc ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-1700ACIN-200V CF-S4(2pcs/set)
External fan model FM-1700ACOUT-200V

Performance diagram

能力グラフ

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

 

 

OCA-S2300AC-A200

OCA-S2300AC-A200

 

Cooling capacity

2100/2300W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
●Nut:4 pcs ●Drain hose:1 pc(5m) ●L joint:2 pcs ●Terminal board:1 pc 
●Packing:1 pc ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-2300ACIN-200V CF-S5(2pc/set)
External fan model FM-2300ACOUT-200V

Performance diagram

能力グラフ

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

 

 

OCA-S3000AC-A200

OCA-S3000AC-A200

 

Cooling capacity

2700/3000W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
●Nut:4 pcs ●Drain hose:1 pc(5m) ●L joint:2 pcs ●Terminal board:1 pc 
●Packing:1 pc ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-3000ACIN-200V CF-S6(2pcs/set)
External fan model FM-3000ACOUT-200V

Performance diagram

能力グラフ

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

 

Option/Related products

Adjustable louver set

 

Cool air is directly blown to the heat source to prevent local temperature rise as well as creating uniform temperature in the enclosure.

Duct kit

 

Use of Duct kit allows cooling from a separately-placed COOLCABI.

Drain evaporator

 

Free from troublesome drain treatment and no more drain worrying about drainage problem.

Self-winding filter

くるくるフィルター

 

Roll filter is wound up automatically by motor.Free yourself from troublesome filter maintenance work.

Cautions

・Locate the unit so as to assure good ventilation and distance of at least 200mm from the walls or other units.
・Failure to this may degrade cooling performance of the unit and cause condensation.
・Setting temperature should be basically at 35℃. Avoid setting at an unnecessarily low value.
・Electrical connection should be made via appropriate circuit breakers.
・Do not use this product in the following places.
 --A place where corrosive or flammable gases exist in the air, or where the insulation destruction occurs
 --A place where the product may be subject to shock or vibration.
・Make sure that electrical wiring work is done by qualified electrician.
・Check for damage on packaging when the product is delivered.
・Any packaging damage may be a cause of malfunction. Make sure that the packaging is not damaged on delivery and contact your supplier.
・Disposal of refrigerant and oil sealed in the cooling circuit should be dealt with only by professional services.


Gallery

Standard series Standard type Roof mounting