    Standard series Condensate-free type

    Standard series Condensate-free type

    Standard series Condensate-free type

    Standard series Condensate-free type

    Condensate-free type

    COOLCABI スタンダードシリーズ

     

    Features

    Type of mounting Environment Cooling method Type Functions
    External only Duct kit (Option) Adjustable louver(Option) Indoor Compressor Condensate-free Energy-saving mode Display

     

    Certificates/Approvals

    EU RoHS2
    China RoHS CE UL CSA PSE

     

     

    Model/Specification

    Model OCA-S350BCD-A200 OCA-S700BCD-A200 OCA-S1300BCD-A200 OCA-S2300BCD-A200
    Type of mounting Lateral mounting (External only)
    Cooling capacity *1 300/350W 600/700W 1150/1300W 2100/2300W
    Rated voltage(50/60Hz) Single phase 200VAC Three phase 200VAC
    Current consumption
    *2
    Rated 1.4/1.4A 2.1/2.2A 3.5/3.6A 3.5/3.6A
    During condensate evaporation*3 1.3/1.2A 2.1/2.1A 3.4/3.5A 3.4/3.7A
    Max. 1.5/1.5A 2.4/2.6A 4.1/4.4A 4.0/4.4A
    Starting current 3.7/3.6A 6.1/5.9A 12.6/11.9A 14.6/14.8A
    Power consumption
    *2
    Rated 235/260W 390/425W 630/705W 975/1115W
    During condensate evaporation*3 225/240W 380/410W 625/695W 960/1150W
    Max. 270/295W 455/510W 760/875W 1160/1390W
    Comp.motor output 100W 250W 400W 650W
    Working temperature *4 +20 to +50℃
    Working humidity Not exceeding 85%RH, free from condensation
    Noise(Charactristic A) 62dB(A) 65dB(A) 65dB(A) 68dB(A)
    Temp. setting range*4 +30 to +45℃ (Initial setting +35℃)
    Display Innter temperature/Alarm code/Operation lamp/Alarm lamp
    Functions Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection, Maintenance reminder, Forced cooling operation for inspection
    External output Alarm output 1a 240V 1.5A×2 (COMMON)
    Vibration withstand Vibration frequency 10 to 150Hz, Acceleration 1.0G, Sweep cycle 20 times
    Protection category*5 Internal circuit IP54 equivalent
    Conformity to standards EMC Directive EN61000-6-2, EN61000-6-4 complaint
    LV directive EN60335-1, EN60335-2-40, EN62233
    Environment RoHS2
    Refrigerant R134a(130g) R134a(190g) R407C(355g) R407C (620g)
    GWP *6 1430
    Color Beige(5Y7/1 corresponding)
    Dimensions(mm) W300×H500×D200 W350×H600×D200 W390×H900×D250 W450×H1150×D250
    Weight 17.0kg 22.0kg 34.0kg 52.0kg
    *1 Nominal value when both of internal and external temperatures are +35℃.
    *2 Nominal values at 35 and 40%RH and inside condtion of 35℃ without drainage and “Max.” values are for outside condition of 50,40%RH and inside condtion of 35℃ without drainage.
    *3 Nominal values with maximum condensate generation when temperatures and humidities both inside and outside the enclosure are 35℃, 85%RH.
    *4 Use only within the specified temperature range.
    *5 Except drain pipe
    *6 By IPCC 4th Report 2007

     


    Product lineup
     

    OCA-S350BCD-A200

    OCA-S350BCD-A200

     

    Cooling capacity

    300/350W(50/60Hz)

    A complete set of supply

    ●COOLCABI:1 pc ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
    ●Nut:4 pcs ●Packing:1 roll ●Drain hose:1 pc(2m) ●Terminal board:1 pc 
    ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

    Consumable parts

    Replacement fan Replacement filter REplacement evaporation sheet
    Internal fan model FM-350BCDIN-200V CF-S1(2pcs/set) CJ-S1(1pc)
    External fan model FM-350BCDOUT-200V

    Performance diagram

    能力グラフ

     

    Dimensional drawing

    外形寸法図

     

    Mounting cutout

    パネルカット図

     

     

     

    OCA-S700BCD-A200

    OCA-S700BCD-A200

     

    Cooling capacity

    600/700W(50/60Hz)

    A complete set of supply

    ●COOLCABI:1 pc ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
    ●Nut:4 pcs ●Packing:1 roll ●Drain hose:1 pc(2m) ●Terminal board:1 pc 
    ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

    Consumable parts

    Replacement fan Replacement filter Replacement evaporation sheet
    Internal fan model FM-700BCDIN-200V CF-S1(2pcs/set) CJ-S2(1 pc.)
    External fan model FM-700BCDOUT-200V

    Performance diagram

    能力グラフ

     

    Dimensional drawing

    外形寸法図

     

    Mounting cutout

    パネルカット図

     

     

     

    OCA-S1300BCD-A200

    OCA-S1300BCD-A200

     

    Cooling capacity

    1150/1300W(50/60Hz)

    A complete set of supply

    ●COOLCABI:1 pc ●Fixing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs 
    ●Nut:6 pcs ●Packing:1 roll ●Drain hose:1 pc(2m) ●Terminal board:1 pc 
    ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

    Consumable parts

    Replacement fan Replacement filter Replacement evaporaton sheet
    Internal fan model FM-1300BCDIN-200V CF-S8(2pcs/set) CJ-S3(1 pc)
    External fan model FM-1300BCDOUT-200V

    Peformance diagram

    能力グラフ

     

    Dimensional drawing

    外形寸法図

     

    Mounting cutout

    パネルカット図

     

     

     

    OCA-S2300BCD-A200

    OCA-S2300BCD-A200

     

    Cooling capacity

    2100/2300W(50/60Hz)

    A complete set of supply

    ●COOLCABI:1 pc ●Fixing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs 
    ●Nut:6 pcs ●Packing:1 roll ●Drain hose:1 pc(2m) ●Terminal board:1 pc 
    ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

    Consumable parts

    Replacement fan Replacement filter Replacement evaporation sheet
    Internal fan model FM-2300BCDIN-200V CF-S2(2pcs/set) CJ-S4(1 pc)
    External fan model FM-2300BCDOUT-200V

    Performance diagram

    能力グラフ

     

    Dimensional drawing

    外形寸法図

     

    Mounting cutout

    パネルカット図

     

     

    Option/Related products

    Adjustable louver set

     

    Cool air is directly blown to the heat source to prevent local temperature rise as well as creating uniform temperature in the enclosure.

    Duct kit

     

    Use of Duct kit allows cooling from a separately-placed COOLCABI.

    Drain evaporator

     

    Free from troublesome drain treatment and no more drain worrying about drainage problem.

    Self-winding filter

    くるくるフィルター

     

    Roll filter is wound up automatically by motor.Free yourself from troublesome filter maintenance work.


    Cautions

    ・Locate the unit so as to assure good ventilation and distance of at least 200mm from the walls or other units.
    ・Failure to this may degrade cooling performance of the unit and cause condensation.
    ・Setting temperature should be basically at 35℃. Avoid setting at an unnecessarily low value.
    ・Electrical connection should be made via appropriate circuit breakers.
    ・Do not use this product in the following places.
     --A place where corrosive or flammable gases exist in the air, or where the insulation destruction occurs
     --A place where the product may be subject to shock or vibration.
    ・Make sure that electrical wiring work is done by qualified electrician.
    ・Check for damage on packaging when the product is delivered.
    ・Any packaging damage may be a cause of malfunction. Make sure that the packaging is not damaged on delivery and contact your supplier.
    ・Disposal of refrigerant and oil sealed in the cooling circuit should be dealt with only by professional services.