    Standard series Bottom flow type

    Standard series Bottom flow type

    Standard series Bottom flow type

    Standard series Bottom flow type

    Blows cool air from the lower side.

    COOLCABI スタンダードシリーズ

     

    Features

    Type of mounting environment Cooling method Type Functions
    Lateral/Rececced Duct kit (Option) Indoor Compressor Bottom flow Energy-saving mode Display

     

    Certificates/Approvals

    EU RoHS2
    China RoHS CE UL CSA PSE
     

     

     

    Model/Specification

    Model OCA-S300BC-A200-R OCA-S600BC-A200-R OCA-S1000BC-A200-R OCA-S1600BC-A200-R OCA-S2200BC-A200-R OCA-S2900BC-A200-R
    Type of mounting Lateral mounting
    Cooling capacity *1 240/290W 440/550W 720/920W 1290/1440W 1880/2070W 2370/2640W
    Rated voltage(50/60Hz) Single phase 200VAC Three phase 200VAC
    Current consumption *2 Rated 1.5/1.3A 2.1/2.1A 3.5/3.6A 4.2/4.3A 3.5/3.7A 4.8/5.8A
    Max. 1.6/1.6A 2.4/2.7A 4.2/4.4A 4.9/5.5A 4.0/4.4A 5.8/6.3A
    Starting current 3.8/3.7A 5.9/5.7A 12.5/11.9A 14.4/13.8A 12.6/14.2A 20.0/19.0A
    Power consumption *2 Rated 255/260W 380/405W 635/715W 770/860W 980/1125W 1320/1460W
    Max. 290/305W 455/525W 775/850W 930/1090W 1180/1380W 1815/1965W
    Comp. motor output 100W 250W 400W 470W 650W 900W
    Working temperature *3 +20 to +50℃
    Working humidity Not exceeding 85%RH, free from condensation
    Noise(Charactristic A) 65dB(A) 65dB(A) 65dB(A) 67dB(A) 67dB(A) 69dB(A)
    Temp. setting range *3 +30 to +45℃ (Initial setting +35℃)
    Display Innter temperature/Alarm code/Operation lamp/Alarm lamp
    Functions Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection, Maintenance reminder, Forced cooling operation for inspection
    External output Alarm output 1a 240V 1.5A×2(COMMON)
    Vibration withstand Vibration frequency 10 to 150Hz, Acceleration 1.0G, Sweep cycle 20 times
    Protection category*4 Internal circuit IP54 equivalent
    Conformity to standards EMC Directive EN61000-6-2,EN61000-6-4 complaint
    LV directive EN60335-1, EN60335-2-40, EN62233
    Environment RoHS2
    Refrigerant R134a
    (100g)
    R134a
    (170g)
    R407C
    (400g)
    R407C
    (450g)
    R407C
    (730g)
    R407C
    (980g)
    GWP *5 1430 1770
    Color Beige(5Y7/1 corresponding)
    Dimensions(mm) W300×H500
    ×D150
    W300×H550
    ×D200
    W350×H900
    ×D200
    W390×H950
    ×D220
    W450×H1150
    ×D220
    W450×H1350
    ×D220
    Weight 16.0kg 18.0kg 33.0kg 36.0kg 52.0kg 59.0kg
    *1 Nominal value when both of internal and external temperatures are +35℃.
    *2 Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max”.
    *3 Use only within the specified temperature range.
    *4 Except drain pipe
    *5 By IPCC 5th Report 2013

     


    Product lineup
     

    OCA-S300BC-A200-R

    OCA-S300BC-A100/A200

     

    Cooling capacity

    240/290W(50/60Hz)

    A complete set of supply

    ●COOLCABI:1 pc ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
    ●Nut:4 pcs ●Packing:1 roll ●Drain hose:1 pc(2m) ●Terminal board:1 pc 
    ●Alarm explanation sheet:1 sheet   ●Instruction manual:1 copy

    Consumable parts

    Replacement fan Replacement filter
    Internal fan model FM-300BCIN-200V CF-S1
    (2pcs/set)
    External fan model FM-300BCOUT-200V

    Performance diagram

    能力グラフ

     

    Dimensional drawing

    外形寸法図

     

    Mounting cutout

    パネルカット図

     

    Mounting view

    取付図

     


     

    OCA-S600BC-A200-R

    OCA-S600BC-A100/A200

     

    Cooling capacity

    440/550W(50/60Hz)

    A complete set of supply

    ●COOLCABI:1 pc ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
    ●Nut:4 pcs ●Packing:1 roll ●Drain hose:1 pc(2m) ●Terminal board:1 pc 
    ●Alarm explanation sheet:1 sheet  ●Instruction manual:1 copy

    Consumable parts

    Replacement fan Replacement filter
    Internal fan model FM-600BCIN-200V CF-S1
    (2pcs/set)
    External fan model FM-600BCOUT-200V

    Performance diagram

    能力グラフ

     

    Dimensional drawing

    外形寸法図

     

    Mounting cutout

    パネルカット図

     

    Mounting view

    取付図

     


     

    OCA-S1000BC-A200-R

    OCA-S1000BC-A200

     

    Cooling capacity

    720/920W(50/60Hz)

    A complete set of supply

    ●COOLCABI:1 pc ●Fixing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs 
    ●Nut:6 pcs ●Packing:1 roll ●Drain hose:1 pc(2m) ●Terminal board:1 pc 
    ●Alarm explanation sheet:1 sheet  ●Instruction manual:1 copy

    Consumable parts

    Replacement fan Replacement filter
    Internal fan model FM-1000BCIN-200V CF-S2
    (2pcs/set)
    External fam model FM-1000BCOUT-200V

    Performance diagram

    能力グラフ

     

    Dimensional drawing

    外形寸法図

     

    Mounting cutout

    パネルカット図

     

    Mounting view

    取付図

     


     

    OCA-S1600BC-A200-R

    OCA-H1600BC-A200-R

     

    Cooling capacity

    1290/1440W(50/60Hz)

    A complete set of supply

    ●COOLCABI:1 pc ●Fixing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs 
    ●Nut:6 pcs ●Packing:1 roll ●Drain hose:1 pc(2m) ●Terminal board:1 pc 
    ●Alarm explanation sheet:1 sheet  ●Instruction manual:1 copy

    Consumable parts

    Replacement fan Replacement filter
    Internal fan model FM-1600BCIN-200V CF-S3
    (2pcs/set)
    External fan model FM-1600BCOUT-200V

    Performance diagram

    能力グラフ

     

    Dimensional drawing

    外形寸法図

     

    Performance diagram

    パネルカット図

     

    Mounting view

    取付図

     


     

    OCA-S2200BC-A200-R

    OCA-S2200BC-A200

     

    Cooling capacity

    1880/2070W(50/60Hz)

    A complete set of supply

    ●COOLCABI:1 pc ●Fixing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs 
    ●Nut:6 pcs ●Packing:1 roll ●Drain hose:1 pc(2m) ●Terminal board:1 pc 
    ●Alarm explanation sheet:1 sheet   ●Instruction manual:1 copy

    Consumable parts

    Replacement fan Replacement filter
    Internal fan model FM-2200BCIN-200V CF-S7
    (2pcs/set)
    External fan model FM-2200BCOUT-200V

    Performance diagram

    能力グラフ

     

    Dimensional drawing

    外形寸法図

     

    Mounting cutout

    パネルカット図

     

    Mounting view

    取付図

     


     

    OCA-S2900BC-A200-R

    OCA-S2900BC-A200

     

    Cooling capacity

    2370/2640W(50/60Hz)

    A complete set of supply

    ●COOLCABI:1 pc ●Fixing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs 
    ●Nut:6 pcs ●Packing:1 roll ●Drain hose:1 pc(2m) ●Terminal board:1 pc 
    ●Alarm explanation sheet:1 sheet   ●Instruction manual:1 copy

    Consumable parts

    Replacement fan Replacement gilter
    Internal fan model FM-2900BCIN-200V CF-S7
    (2pcs/set)
    External fan model FM-2900BCOUT-200V

    Performance diagram

    能力グラフ

     

    Dimensional drawing

    外形寸法図

     

    Mounting cutout

    パネルカット図

     

    Mounting view

    取付図

     


    Opttion/Related products

    Duct kit

     

    Use of Duct kit allows cooling from a separately-placed COOLCABI.

    Drain evaporator

     

    Free from troublesome drain treatment and no more drain worrying about drainage problem.

    Self-winding filter

    くるくるフィルター

     

    Roll filter is wound up automatically by motor.Free yourself from troublesome filter maintenance work.
     

    Cautions

    ・Locate the unit so as to assure good ventilation and distance of at least 200mm from the walls or other units.
    ・Failure to this may degrade cooling performance of the unit and cause condensation.
    ・Setting temperature should be basically at 35℃. Avoid setting at an unnecessarily low value.
    ・Electrical connection should be made via appropriate circuit breakers.
    ・Do not use this product in the following places.
     -A place where corrosive or flammable gases exist in the air, or where the insulation destruction occurs.
     -A place where the product may be subject to shock or vibration.
    ・Make sure that electrical wiring work is done by qualified electrician.
    ・Check for damage on packaging when the product is delivered.
    ・Any packaging damage may be a cause of malfunction.Make sure that the packaging is not damaged on delivery and contact your supplier.
    ・Disposal of refrigerant and oil sealed in the cooling circuit should be dealt with only by professional services.


    Gallery

    Standard series Bottom flow type