• Auroratoto
  • https://sistema.consuma.com.br/assets/
  • https://mpp.tangerangselatankota.go.id/xgen/
  • https://ncc.potensi-utama.ac.id/images/
  • https://halobengkel.com/
  • https://jdih.selumakab.go.id/assets/sgacor/
  • https://halobengkel.com/wp-includes/assets/
  • https://genetrap.tigem.it/public/
  • https://kebidanan.pkr.ac.id/wp-content/dana/
  • https://blog.stiab-jinarakkhita.ac.id/wp-includes/x200/

  • Warning: session_start(): Cannot send session cookie - headers already sent by (output started at /home/ohmdenki/public_html/index.php:6) in /home/ohmdenki/public_html/app/autoload.php on line 2

    Warning: session_start(): Cannot send session cache limiter - headers already sent (output started at /home/ohmdenki/public_html/index.php:6) in /home/ohmdenki/public_html/app/autoload.php on line 2
    International model Standard CCC type Lateral mounting

    International model Standard CCC type Lateral mounting

    International model Standard CCC type Lateral mounting

    International model Standard CCC type Lateral mounting

    Standard CCC type.
    Lateral mounting (220VAC/50Hz)

    COOLCABI スタンダードシリーズ CCC規格認証品

     

    Features

    Type of mounting Environment Cooling method Functions
    Lateral/Rececced Duct kit (Option) Adjustable louver (Option) Indoor Compressor Energy-saving mode Display

     

    Certificates/Approvals

    EU RoHS2 China RoHS CE UL CCC CSA PSE
     

     

     

    Model/Specification

    Model OCA-S300BC-A220-CN OCA-S600BC-A220-CN OCA-S1000BC-A220-CN OCA-S1600BC-A220-CN
    Type of mounting Lateral mounting
    cooling capacity *1 250W 500W 800W 1450W
    Rated voltage(50Hz) single phase 220VAC
    Current consumption *2 Rated 1.1A 2.3A 3.5A 4.0A
    Max. 1.3A 2.7A 4.0A 4.8A
    Starting current 3.0A 9.0A 13.8A 17.2A
    Power consumption *2 Rated 230W 430W 665W 860W
    Max. 265W 525W 790W 1025W
    Comp. motor output 200W 300W 450W 568W
    Working temperature *3 +20 to +50℃
    Working humidity Not exceeding 85%RH, free from condensation
    Noise
    (Charactristic A)
    63dB(A) 65dB(A) 65dB(A) 65dB(A)
    Temp. setting range *3 +30 to+45℃ (Initial setting +35℃)
    Display Innter temperature/Alarm code/Operation lamp/Alarm lamp
    Functions Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection, Maintenance reminder, Forced cooling operation for inspection
    External output Alarm output 1a 240V 1.5A×2(COMMON)
    Vibration withstand Vibration frequency 10 to 55Hz, Amplitude 0.15mm, Sweep cycle 10 times
    Protection category *4 Internal circuit IP54 equivalent
    CCC standard CCC certification(GB4706.1,GB4706.32,GB4343.1,GB17625.1)
    Environment RoHS
    Refrigerant R134a(190g) R134a(290g) R407C (600g) R407C (560g)
    GWP*5 1430 1770
    Color Beige(5Y7/1 corresponding)
    Dimensions(mm) W300×H500×D150 W300×H550×D200 W350×H900×D200 W390×H950×D220
    Weight 15.5kg 18.5kg 32.0kg 39.5kg
    *1 Nominal value when both of internal and external temperatures are +35℃. By attaching the provided louver, the capacity reduces by up to 5%.
    *2 Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max”.
    *3 Use only within the specified temperature range.
    *4 Except drain pipe
    *5 By IPCC 4th Report 2007

     


    Product lineup
     

    OCA-S300BC-A220-CN

    OCA-S300BC-A220-CN

     

    Cooling capacity

    250W

    A complete set of supply

    ●COOLCABI:1 pc ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
    ●Nut:4 pcs ●Packing:1 roll ●Drain hose:1 pc(2m) ●Terminal board:1 pc 
    ●Alarm explanation sheet:1 sheet   ●Instruction manual:1 copy
    ●Adjustable louver:1 pc ●Screws for louver:4 pcs

    Consumable parts

    Replacement fan Replacement filter
    Internal fan model FM-300BCIN-A220-CN CF-S1(2pcs/set)
    External fan model FM-300BCOUT-A220-CN

    Performance diagram

    能力グラフ

     

    Dimensional drawing

    外形寸法図

     

    Mounting cutout

    パネルカット図

     

    Mounting view

    取付図

     


     

    OCA-S600BC-A220-CN

    OCA-S600BC-A220-CN

     

    Cooling capacity

    500W

    A complete set of supply

    ●COOLCABI:1 pc ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
    ●Nut:4 pcs ●Packing:1 roll ●Drain hose:1 pc(2m) ●Terminal board:1 pc 
    ●Alarm explanation sheet:1 sheet   ●Instruction manual:1 copy
    ●Adjustable louver:1 pc  ●Screws for louver:4 pcs

    Consumable parts

    Replacement fan Replacement filter
    Internal fan model FM-600BCIN-A220-CN CF-S1(2pcs/set)
    External fan model FM-600BCOUT-A220-CN

    Performance diagram

    能力グラフ

     

    Dimensional drawing

    外形寸法図

     

    Mounting cutout

    パネルカット図

     

    Mounting view

    取付図

     


     

    OCA-S1000BC-A220-CN

    OCA-S1000BC-A220-CN

     

    Cooling capacity

    800W

    A complete set of supply

    ●COOLCABI:1 pc ●Fixing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs 
    ●Nut:6 pcs ●Packing:1 roll ●Drain hose:1 pc(2m) ●Terminal board:1 pc 
    ●Alarm explanation sheet:1 sheet  ●Instruction manual:1 copy
    ●Adjustable louver:2 pcs   ●Screws for louver:8 pcs

    Consumable parts

    Replacement fan Replacement filter
    Internal fan model FM-1000BCIN-A220-CN CF-S2(2pcs/set)
    External fan model FM-1000BCOUT-A220-CN

    Performance diagram

    能力グラフ

     

    Dimensional drawing

    外形寸法図

     

    Mounting cutout

    パネルカット図

     

    Mounting view

    取付図

     


     

    OCA-S1600BC-A220-CN

    OCA-S1600BC-A220-CN

     

    Cooling capacity

    1450W

    A complete set of supply

    ●COOLCABI:1 pc ●Fixing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs 
    ●Nut:6 pcs ●Packing:1 roll ●Drain hose:1 pc(2m) ●Terminal board:1 pc 
    ●Alarm explanation sheet:1 sheet   ●Instruction manual:1 copy
    ●Adjustable louver:2 pcs   ●Screws for louver:8 pcs

    Consumable parts

    Replacement fan Replacement filter
    Internal fan model FM-1600BCIN-A220-CN CF-S3(2pcs/set)
    External fan model FM-1600BCOUT-A220-CN

    Performance diagram

    能力グラフ

     

    Dimensional drawing

    外形寸法図

     

    Mounting cutout

    パネルカット図

     

    Mounting view

    取付図

     


    Option/Related products

    Adjustable louver set

     

    Cool air is directly blown to the heat source to prevent local temperature rise as well as creating uniform temperature in the enclosure.

    Duct kit

     

    Use of Duct kit allows cooling from a separately-placed COOLCABI.

    Drain evaporator

     

    Free from troublesome drain treatment and no more drain worrying about drainage problem.

    Self-winding filter

    くるくるフィルター

     

    Roll filter is wound up automatically by motor.Free yourself from troublesome filter maintenance work.
     

    Cautions

    ・Locate the unit so as to assure good ventilation and distance of at least 200mm from the walls or other units.
    ・Failure to this may degrade cooling performance of the unit and cause condensation.
    ・Setting temperature should be basically at 35℃. Avoid setting at an unnecessarily low value.
    ・Electrical connection should be made via appropriate circuit breakers.
    ・Do not use this product in the following places.
     --A place where corrosive or flammable gases exist in the air, or where the insulation destruction occurs
     --A place where the product may be subject to shock or vibration.
    ・Make sure that electrical wiring work is done by qualified electrician.
    ・Check for damage on packaging when the product is delivered.
    ・Any packaging damage may be a cause of malfunction. Make sure that the packaging is not damaged on delivery and contact your supplier.
    ・Disposal of refrigerant and oil sealed in the cooling circuit should be dealt with only by professional services.


    Gallery

    International model Standard CCC type Lateral mounting