Cable gland and terminal board are integrated.
Protection category | Color | Rated voltage | Rated current | Oilproof | Weatherproof | Number of terminals |
IP67 | Black/Light gray/Beige | 300V | 15A | ✓ | ✓ | 5P/7P/11P |
EU RoHS2 | China RoHS | CE | UL | CSA | PSE |
Model | Rated voltage | Nominal section area of cable | Number of terminals | Terminal screw | Weight (*1) |
Q'ty per package | ||
Black | Light gray | Beige | ||||||
JB-W305 | JB-W305C1 | JB-W305BJ | AC/DC 300V 15A |
1.25mm2 or less |
5P | M3×8 Free terminal screw |
100g | 1pc |
JB-W307 | JB-W307C1 | JB-W307BJ | 7P | 117g | ||||
JB-W311 | JB-W311C1 | JB-W311BJ | 11P | 170g |
Model | Rated voltage | Nominal section area of cable | Number of terminals | Terminal screw | Weight (*1) |
Q'ty per package | ||
Black | Light gray | Beige | ||||||
JB-W305E | - | JB-W305EBJ | AC/DC 300V 15A |
1.25mm2 or less |
5P | M3×8 Free terminal screw |
100g | 1pc |
JB-W307E | - | JB-W307EBJ | 7P | 117g | ||||
JB-W311E | - | JB-W311EBJ | 11P | 170g |
Model of Rubber bushing | Applicable cable diameter(mm) | Q'ty |
G13-09A/09AE | Ø6 to 9 | 1 |
G13-404/404E | Ø 3 to 4(4 holes) | 1 |
Model of Plugging bars | Specifications | Q'ty |
BB-40S | G13-404/404E |
2 |
Model of Rubber bushing | Applicable cable diameter(mm) | Q'ty |
G13-11/11E | Ø8.5 to 11.5 | 1 |
Model of Shorting bar | Specifications | Q'ty |
JB-SB152 | 2P | 1 |
Model of Rubber bushing | Applicable cable diameter(mm) | Q'ty |
G13-11/11E | Ø8.5 to 11.5 | 1 |
G13-404/404E | Ø3 to 4(4 holes) | 1 |
Model of Plugging bars | Specifications | Q'ty |
BB-40S | G13-404/404E |
2 |
Model of Rubber bushing | Applicable cable diameter(mm) | Q'ty |
G13-09A/09AE | Ø6 to 9 | 1 |
Model of Shorting bar | Specification | Q'ty |
JB-SB152 | 2P | 1 |
Model of Rubber bushing | Applicable cable diameter (mm) | Q'ty |
G13-11/11E | Ø8.5 to 11.5 | 1 |
G13-404/404E | Ø3 to 4(4 holes) | 2 |
Model of Plugging bar | Specification | Q'ty |
BB-40S | G13-404/404E |
4 |
Model of Rubber bushing | Applicable cable diameter(mm) | Q'ty |
G13-09A/09AE | Ø6 to 9 | 1 |
G13-13/13E | Ø11 to 13 | 1 |
Model of Shorting bar | Specification | Q'ty |
JB-SB154 | 4P | 1 |
1.Insert cables from the openings on each end (through the CAPCON) and crimp the fork terminals.
【Caution】Make sure to use an insulated sleeve with the forked terminal to keep an appropriate insulation distance.Failure to this may lead to a short circuit.
2.Install the fork terminals in the JOIBOX terminal strip and tighten them with the screws provided.
【Caution】To avoid damage by heating, observe the following matters without fail.
・Make sure that the screws have been tightly secured.
・Avoid connections as shown in the examples shown.
3.Tighten the (CAPCON) dome nut to fasten the cables.
【G13-404(E)Rubber Bushing Instruction】
Insert the plugging bars into all unused holes. Place cables and plugging vars in a diagonal position when
2 cables are inserted as shown the above.