Female threaded entries allow a wide variety of connector selection for your particular wiring requirements
Protection category | Color | Rated volage | Rated volatge | Oilproof | Weatherproof | Number of terminals |
IP67 | Black/Light gray/Beige | 300V | 15A | ✓ | ✓ | 5P/7P/11P |
EU RoHS2 | China RoHS | CE | UL | CSA | PSE |
Model | Rated voltage | Nominal section area of cable | Number of terminals | Terminal screw | Weight (*1) |
Q'ty per package |
|||
Black | Light gray | Beige | |||||||
JB-WG305 | JB-WG305C1 | JB-WG305BJ | AC/DC 300V 15A |
1.25mm2 or less |
5P | M3×8 Free terminal screw |
98g | 1 pc | |
JB-WG307 | JB-WG307C1 | JB-WG307BJ | 7P | 124g | |||||
JB-WG311 | JB-WG311C1 | JB-WG311BJ | 11P | 208g |
Model | Rated voltage | Nominal section area of cable | Number of terminals | Terminal screw | Weight (*1) |
Q'ty per package |
||
Black | Light gray | Beige | ||||||
JB-WG305E | - | JB-WG305EBJ | AC/DC 300V 15A |
1.25mm2 or less |
5P | M3×8 Free terminal screw |
98g | 1 pc |
JB-WG307E | - | JB-WG307EBJ | 7P | 124g | ||||
JB-WG311E | - | JB-WG311EBJ | 11P | 208g |
Model | Applicable cable diameter | Numbers of cavity |
OA-WW16- 04/12(E) |
Ø4 to 12 | 1 |
OA-WW16- 08/15(E) |
Ø8 to 15 |
Model | Applicable cable diameter | Numbers of cavity |
OA-W1606/1606E | Ø4 to 6 | 1 |
OA-W1608/1608E | Ø6 to 8 | |
OA-W1609/1609E | Ø7 to 9 | |
OA-W1611/1611E | Ø9 to 11 | |
OA-W1613/1613E | Ø11 to 13 | |
OA-W1614/1614E | Ø13 to 14 |
Model | Applicable cable diameter | Numbers of cavity |
OA-W16-224/224E | Ø1.7 to 2.2 | 4 |
OA-W16-334/334E | Ø2.2 to 3.3 | 4 |
OA-W16-402/402E | Ø3 to 4 | 2 |
OA-W16-404/404E | 4 | |
OA-W16-503/503E | Ø4 to 5 | 3 |
OA-W16-602/602E | Ø5 to 6 | 2 |
Item | Parameter |
Connector diameter | Ø33mm or less |
Thread | CTG16 |
Item | Parameter |
Connector diameter | Ø35.5mm or less |
Thread | CTG16 |
Model of shorting bar | Specification | Q'ty |
JB-SB152 | 2P | 1 |
Model of shorting bar | Specification | Q'ty |
JB-SB154 | 4P | 1 |
Model of plugging bar | Specification | Q'ty |
JB-BC16□/16E□ | CTG16 for internal thread | 1 |
1.Insert cables from the openings on each end (through the CAPCON) and crimp the fork terminals.
【Cautions】Make sure to use an insulated sleeve with the forked terminal to keep an appropriate insulation distance.Failure to this may lead to a short circuit.
2.Install the fork terminals.
【Cautions】The following matters should be strictly observed. Faulty connections may result in heating or burning.
・Make sure the screws are tightly secured. Check and retighten if necessary.
・Never make connections as shown in the above.