Female threaded entries allow a wide variety of connector selection for your particular wiring requirement. Rated voltage:600V 20A
Protection category | Color | Rated voltage | Rated current | Oilproof | Weatherproof | Number of terminals |
IP67 | Black/Light gray/Beige | 600V | 20A | ✓ | ✓ | 6P |
EU RoHS2 | China RoHS | CE | UL | CSA | PSE |
Model | Rated voltage | Nominal section area of cable | Number of terminals | Terminal screw | Weight (*1) |
Q'ty per package |
||
Black | Light gray | Beige | ||||||
JB-WP166 | JB-WP166C1 | JB-WP166BJ | AC/DC 600V 20A |
2.0mm2 or less |
6P | M3.5×10 Free terminal screw |
122g | 1 pc. |
JB-WP226 | JB-WP226C1 | JB-WP226BJ | 151g |
Model | Rated voltage | Nominal section area of cable | Number of terminals | Terminal screw | Weight (*1) |
Q'ty per package |
||
Black | Light gray | Beige | ||||||
JB-WP166E | - | JB-WP166EBJ | AC/DC 600V 20A |
2.0mm2 or less |
6P | M3.5×10 Free terminal screw |
122g | 1 pc. |
JB-WP226E | - | JB-WP226EBJ | 151g |
Model | Applicable cable diameter | Numbers of cavity |
OA-WW16- 04/12(E) |
Ø4 to 12 | 1 |
OA-WW16- 08/15(E) |
Ø8 to 15 |
Model | Applicable cable diameter | Numbers of cavity |
OA-W1606/1606E | Ø4 to 6 | 1 |
OA-W1608/1608E | Ø6 to 8 | |
OA-W1609/1609E | Ø7 to 9 | |
OA-W1611/1611E | Ø9 to 11 | |
OA-W1613/1613E | Ø11 to 13 | |
OA-W1614/1614E | Ø13 to 14 |
Model | Applicable cable diameter | Numbers of cavity |
OA-W16-224/224E | Ø1.7 to 2.2 | 4 |
OA-W16-334/334E | Ø2.2 to 3.3 | 4 |
OA-W16-402/402E | Ø3 to 4 | 2 |
OA-W16-404/404E | 4 | |
OA-W16-503/503E | Ø4 to 5 | 3 |
OA-W16-602/602E | Ø5 to 6 | 2 |
Model | Applicable cable diameter | Numbers of cavity |
OA-WW22-11/20(E) | Ø11 to 20 | 1 |
Model | Applicable cable diameter | Numbers of cavity |
OA-W2213/2213E | Ø9 to 13 | 1 |
OA-W2216/2216E | Ø13 to 16 | |
OA-W2219/2219E | Ø15 to 19 |
Model | Applicable cable diameter | Numbers of cavity |
OA-W22-604/604E | Ø5 to 6 | 4 |
OA-W22-704/704E | Ø6 to 7 |
Item | Parameter |
Connector diameter | Ø33mm or less |
Thread | CTG16 |
Item | Parameter |
Connector diameter | Ø42mm or less |
Thread | CTG22 |
1.Insert cables from the openings on each end (through the CAPCON) and crimp the fork terminals.
【Cautions】Make sure to use an insulated sleeve with the forked terminal to keep an appropriate insulation distance.Failure to this may lead to a short circuit.
2.Install the fork terminals.
【Cautions】The following matters should be strictly observed. Faulty connections may result in heating or burning.
・Make sure the screws are tightly secured. Check and retighten if necessary.
・Never make connections as shown in the above.