https://duniapermainan.id/https://borobudur.site/https://beritamakan.xyz/http://lesfergusonjr.com/https://www.drafthorsejournal.net/https://ajudanze.us/https://soykb.org/https://www.laoplazahotel.com/https://bidpropamkaltara.com/https://www.inmercociudades.org/https://hanomantoto.vip/https://www.ha-software.com/https://www.demo.mimikakab.go.id/
Non-fluorocarbon Series Condensate-free type

Non-fluorocarbon Series Condensate-free type

Non-fluorocarbon Series Condensate-free type

Non-fluorocarbon Series Condensate-free type

No obligatory inspection by Japanese law required.
Condnsate-free type.

No obligatory inspection by Japanese law required.
Condnsate-free type.

COOLCABI ノンフロンシリーズ

 

Features

Type of mounting Environment Cooling method Type Functions Obligatory inspection by Japanese law
External only Duct kit (Option)
Adjustable louver(Option) Indoor Compressor Condensate-free Energy-saving mode Display N/A

Certificates/Approvals

EU RoHS2 China RoHS CE UL CSA PSE
 

 

 

Model/Specification

Model OCA-
H350BCD-A200
OCA-
H700BCD-A200
OCA-
H1300BCD-A200
OCA-
H2300BCD-A200
Type of mounting Lateral mounting(External only)
Cooling capacity *1 300/350W 600/700W 1100/1250W 2100/2300W
Rated voltage(50/60Hz) Single phase 200VAC Three phase 200VAC
Current consumption
*2
Rated 1.3/1.2A 2.1/2.1A 3.1/2.9A 3.4/3.5A
During condensate evaporation*3 1.3/1.2A 2.1/2.1A 3.1/2.9A 3.4/3.5A
Max. 1.5/1.4A 2.4/2.5A 3.5/3.5A 3.9/4.3A
Starting current 3.6/3.6A 6.6/6.1A 12.0/11.6A 14.6/14.8A
Power consumption
*2
Rated 220/230W 400/410W 540/580W 970/1080W
During condensate evaporation*3 220/230W 400/410W 540/580W 970/1060W
Max. 260/270W 470/500W 630/690W 1160/1330W
Comp. motor output 100W 275W 375W 850W
Working temperature *4 +20 to+50℃
Working humidity Not exceeding 85%RH,free from condensation
Noise(Charactristic A) 62dB(A) 65dB(A) 65dB(A) 69dB(A)
Temp. setting range*4 +30 to+45℃ (Initial setting:+35℃)
Display Innter temperature/Alarm code/Operation lamp/Alarm lamp
Functions Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection,
Maintenance reminder, Forced cooling operation for inspection
External output Alarm output 1a 240V 1.5A×2 (COMMON)
Vibration withstand Vibration frequency 10 to 55Hz, Amplitude0.15mm, Sweep cycle 10 times
Protection category*5 Internal circuit IP54 equivalent
Conformity to standards EMC Directive EN61000-6-2,EN61000-6-4 complaint
LV directive EN60335-1, EN60335-2-40, EN62233
Environment RoHS2
Refrigerant R1234yf(150g) R1234yf(210g) R1234yf (430g) R1234yf (1000g)
GWP*6 <1
Color Powder coating N8 corresponding, N4 corresponding
Dimensions(mm) W300×H500×D200 W350×H600×D200 W390×H900×D252 W450×H1150×D250
Weight 17.0kg 22.0kg 33.0kg 52.0kg
*1 Nominal value when both of internal and external temperatures are +35℃.
*2 Nominal values at 35 and 40%RH and inside condtion of 35℃ without drainage and “Max.” values are for outside condition of 50,40%RH and inside condtion of 35℃ without drainage.
*3 Nominal values with maximum condensate generation when temperatures and humidities both inside and outside the enclosure are 35℃, 85%RH.
*4 Use only within the specified temperature range.
*5 Except drain pipe
*6 By IPCC 5th Report 2013

Product lineup
 

OCA-H350BCD-A200

OCA-H350BCD-A200

 

Cooling capacity

300/350W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc. ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
●Nut:4 pcs ●Packing:1 roll ●Drain hose:1 pc.(2m) ●Terminal board:1 pc. 
●Alarm explanation sheet:1 sheet  ●Instruction manual: 1 copy

Consumable parts

Replacement fan Replacement
filter
Replacement
evaporation sheet
Internal fan model FM-350BCDIN-200V CF-S1
(2 pcs/ set)
CJ-S1
(1 pc.)
External fan model FM-350BCDOUT-200V

Performance diagram

能力グラフ

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

 

 

OCA-H700BCD-A200

OCA-H700BCD-A200

 

Cooling capacity

600/700W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc. ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
●Nut:4 pcs ●Packing:1 roll ●Drain hose:1 pc.(2m) ●Terminal board:1 pc. 
●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

Consumable parts

Replacement fan Replacement
filter
Replacement
evaporation sheet
Internal fan model FM-700BCDIN-200V CF-S1
(2 pcs/set)
CJ-S2
(1 pc.)
External fan model FM-700BCDOUT-200V

Performance diagram

能力グラフ

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

 

 

OCA-H1300BCD-A200

OCA-H1300BCD-A200

 

Cooling capacity

1100/1250W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc. ●Fixing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs 
●Nut:6 pcs ●Packing:1 roll ●Drain hose:1 pc.(2m) ●Terminal board:1 pc 
●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

Consumable parts

Replacement fan Replacement
filter
Replacement
evaporation sheet
Internal fan model FM-1300BCDIN-200V CF-S8
(2pcs/set)
CJ-S3
(1 pc.)
External fan model FM-1300BCDOUT-200V

Performance diagram

能力グラフ

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

 

 

OCA-H2300BCD-A200

OCA-H2300BCD-A200

 

Cooling capacity

2100/2300W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc. ●FIxing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs 
●Nut:6 pcs ●Packing:1 roll ●Drain hose:1 pc(2m) ●Terminal board:1 pc.
●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

Consumable parts

Replacement fan Replacement
filter
Replacement
evaporation sheet
Internal fan model FM-2300BCDIN-200V CF-S2
(2pcs/set)
CJ-S4
(1 pc.)
External fan model FM-2300BCDOUT-200V

Performance diagram

能力グラフ

 

Dimensional drawing

外形寸法図

 

Mounting cutout

パネルカット図

 

 

Option/Related products

Adjustable louver set

 

Cool air is directly blown to the heat source to prevent local temperature rise as well as creating uniform temperature in the enclosure.

Duct kit

 

Use of Duct kit allows cooling from a separately-placed COOLCABI.

Drain evaporator

 

Free from troublesome drain treatment and no more drain worrying about drainage problem.

Self-winding filter

くるくるフィルター

 

Roll filter is wound up automatically by motor.Free yourself from troublesome filter maintenance work.

Cautions

・Locate the unit so as to assure good ventilation and distance of at least 200mm from the walls or other units.
・Failure to this may degrade cooling performance of the unit and cause condensation.
・Setting temperature should be basically at 35℃. Avoid setting at an unnecessarily low value.
・Electrical connection should be made via appropriate circuit breakers.
・Do not use this product in the following places.
 --A place where corrosive or flammable gases exist in the air, or where the insulation destruction occurs.
 --A place where the product may be subject to shock or vibration.
・Make sure that electrical wiring work is done by qualified electrician.
・Check for damage on packaging when the product is delivered.
・Any packaging damage may be a cause of malfunction. Make sure that the packaging is not damaged on delivery and contact your supplier.


Gallery

Non-fluorocarbon Series Condensate-free type