http://www.spinachbase.org/https://duniapermainan.id/https://borobudur.site/https://beritamakan.xyz/http://lesfergusonjr.com/https://www.drafthorsejournal.net/https://ajudanze.us/https://soykb.org/https://www.laoplazahotel.com/https://bidpropamkaltara.com/https://www.inmercociudades.org/https://hanomantoto.vip/https://togeljackpot.bio/https://wsf2024nepal.org/https://www.ha-software.com/https://www.demo.mimikakab.go.id/https://alapp.selumakab.go.id/main/https://www.aveironet.com/https://motocofservice.com/https://missglobalnigeria.com/https://gilchristfliegen.com/https://cosmictoto.id/https://alapp.selumakab.go.id/log/https://borobudurbet-com.net/https://auroratotosatu.net/https://auroratoto-2.com/https://kec-telukkepayang.tanahbumbukab.go.id/lick/index.html
Fan-cooled Plate Cooling type

Fan-cooled Plate Cooling type

Fan-cooled Plate Cooling type

Fan-cooled Plate Cooling type

Directly-cooled plate surface absorbs heats from an object without heat losses

OCE-FP

 

Features

Environment of use Cooling method Heat dissipation Type of cooling
Indoor Thermoelectric Air cooling Plate

 

Certificates/Approvals

EU RoHS China RoHS CE UL CSA PSE

Cooling cycle

冷却サイクル

 

Theremoelectric module absorbs heat from the plate and the cooled plate cools the object through heat transfer materials like thermal conductive grease in direct contact. The absorbed heat on plate side and the generated heat are cooled by fan to be dissipated through a heat conductive material like aluminum from the opposite side of a thermoelectric module. (*1)
(*1) The heat absorbed through the heat radiation fin is exhausted from the fan on heat dissipation side.

Example of use

使用例

 

Model/Specifications

Model OCE-F15P-D12 OCE-F40P-D24 OCE-F80P-D24
Cooling method Fan-cooled Plate cooling
Cooling capacity *1 20W 55W 110W
Heating capacity *2 60W 160W 320W
Max. temperture difference in cooling *3 35K 40K 44K
Rated voltage Fan 12VDC ±5% 24VDC ±5%
Peltier
Current consumption *4 3.5A or less 4.5A or less 9.0A or less
Starting current *5 4.5A 5.7A 11.3A
Working temperature 0 to +60℃
Working humidity Max. 80%RH, free from condensation
Noise 40dB(A) 45dB(A)
Max. allowable temeprature for Cooling palte +80℃
Max. allowable temeprature for Dissipation fin base +80℃
Vibration resistance Vibration frequency 10-55Hz Total amplitude 0.7mm
Cycle 5 min  X, Y and Z axis 25min each
Conformity to standards Environment RoHS
Dimensions (mm)※6 W70×H90×D79 W110×H135×D99 W220×H150×D113
Weight 0.4kg 1.0kg 2.1kg
*1 Nominal value at 30℃ ambient temp. by applying our capacity measurement method by product type
*2 Nominal value when both ambient and plate temperatures are 30℃
*3 Temperature difference between ambient air and cooling part when ambient temp. is 30℃ and heat load on plate surface is zero
*4 Rated value when the unit runs cooling operation at 30℃ ambient temp. (The value varies depending on temperature. See the table below. )
*5 Value at 30℃ ambient temp. (The value varies depending on temperature. See the table below. )
*6 Terminal board and projections are excluded.

Correlation between temperature and current value

  Ambient temperature 0℃ 15℃ 30℃ 45℃ 60℃
OCE-F15P-D12
(incl. 0.26A for fan)
Rated current consumption (A) 4.2 4.0 3.5 3.4 3.2
Starting current (A) 5.0 4.8 4.5 4.3 4.0
OCE-F40P-D24
(incl. 0.14A for fan)
Rated current consumption (A) 5.6 5.0 4.5 4.3 4.1
Starting current (A) 6.4 6.0 5.7 5.3 4.9
OCE-F80P-D24
(incl. 0.25A for fan)
Rated current consumption (A) 11.1 10.1 9.0 8.7 8.3
Starting current (A) 12.7 12.0 11.3 10.5 9.8

 


Product lineup

OCE-F15P-D12

OCE-F15P-D12

 

Cooling capacity

20W

A complete set of supply

BOXCOOL : 1 unit Instruction manual : 1 copy Heat insulator for mounting hole : 4 pcs.

Performance chart

能力特性図

 

Achieving temperature characteristic chart

到達温度特性図

 

Dimensional drawing

外形寸法図

 

Mounting cutout

取付穴加工図

 


OCE-F40P-D24

OCE-F40P-D24

 

Cooling capacity

55W

A complete set of supply

BOXCOOL : 1 unit Instruction manual : 1 copy Heat insulator for mounting hole : 4 pcs.

Performance chart

能力特性図

 

Achieving temperature characteristic chart

到達温度特性図

 

Dimensional drawing

外形寸法図

 

Mounting cutout

取付穴加工図

 


OCE-F80P-D24

OCE-F80P-D24

 

Cooling capacity

110W

A complete set of supply

BOXCOOL : 1 unit Instruction manual : 1 copy Heat insulator for mounting hole : 4 pcs.

Performance chart

能力特性図

 

Achieving temperature characteristic chart

到達温度特性図

 

Dimensional drawing

外形寸法図

 

Mounting cutout

取付穴加工図

 

System combination

By combination of BOXCOOL and components, various systems having different operation control from continuous operation to precise inversion control can be built.

①Continuous cooling

Combines BOXCOOL with a power supply for continuous running

連続冷却

 

Component name Model
OCE-F15P-D12 OCE-F40P-D24 OCE-F80P-D24
Switched-mode power supply PBA75F-12-N PBA150F-24-N PBA300F-24
AC wiring *1 WH-A-M4-2
DC wiring WH-P-M4-2、WH-F-M4-2 WH-P-M5-2、WH-F-M5-2
*1 For 100VAC power supply

②Simple thermal control system

ON/OFF control is done by a temperature controller using a contact in the power supply.

簡易冷却温調システム

 

Component name Model
OCE-F15P-D12 OCE-F40P-D24 OCE-F80P-D24
Temperature controller OCE-TC91-8P3-1C OCE-TC91-8Y1-1C
Switched-mode power supply PBA75F-12-NR PBA150F-24-NR PBA300F-24
Temperature sensor OCE-TCPT12 OCE-TCPT13 OCE-TCPT14
AC wiring *1 WH-A-M4-2
Wiring for temperature controller WH-C2
DC wiring WH-P-M4-2、WH-F-M4-2 WH-P-M5-2、WH-F-M5-2
*1 For 100VAC power supply

③Precise inversion control system

Highly precise temperature control is achieved by linear voltage controlled switching of cooling and heating using our Temperature Control system designed for BOXCOOL.

精密反転温調システム

 

Component name Model
OCE-F15P-D12 OCE-F40P-D24 OCE-F80P-D24
Temperature Control System OCE-TCR12075WL OCE-TCR24150WL OCE-TCR24300WL
Temperature Sensor OCE-TCPT12 OCE-TCPT13 OCE-TCPT14
AC wiring ※1 WH-A-M4-2
DC wiring WH-P-M4-2、WH-F-M4-2
*1 For 100VAC power supply

Related products

DIY kit

学習用キット

 

Self-assembling kit of Fan-cooled Plate cooling type for learners. Easy to assemble with a screwdriver.
 

Cautions

・Avoid controlling supply voltage to the fan. Failure to this can be a cause of breakdown of the product.
・Do not use this product in a place where flammable or corrosive gasses, oil fume or any matters that can destroy insulation generate or permeate.
・The site of use should be free from vibration and impact.
・Electrical works required for installation of this product should be done only by professionals or qualified personnel.
・Indoor use only.
・Make sure that the packaging is not damaged on delivery. Any packaging damage can lead to breakdown of the product. Please contact us immediately if any damage is found.


Gallery