http://www.spinachbase.org/https://duniapermainan.id/https://borobudur.site/https://beritamakan.xyz/http://lesfergusonjr.com/https://www.drafthorsejournal.net/https://ajudanze.us/https://soykb.org/https://www.laoplazahotel.com/https://bidpropamkaltara.com/https://www.inmercociudades.org/https://hanomantoto.vip/https://togeljackpot.bio/https://wsf2024nepal.org/https://www.ha-software.com/https://www.demo.mimikakab.go.id/https://alapp.selumakab.go.id/main/https://www.aveironet.com/https://motocofservice.com/https://missglobalnigeria.com/https://gilchristfliegen.com/https://cosmictoto.id/https://alapp.selumakab.go.id/log/https://borobudurbet-com.net/https://auroratotosatu.net/https://auroratoto-2.com/https://kec-telukkepayang.tanahbumbukab.go.id/lick/index.html
Fan-cooled Fluid Cooling type

Fan-cooled Fluid Cooling type

Fan-cooled Fluid Cooling type

Fan-cooled Fluid Cooling type

Meets variety of fluids by selecting liquid contact part from aluminum and titanium

OCE-FL

 

Features

Environment of use Cooling method Heat dissipation Type of cooling
Indoor Thermoelectric Air cooling Fluid cooling

 

Certificates/Approvals

EU RoHS China RoHS CE UL CSA PSE

 

Cooling cycle

冷却サイクル

 

Fluid flown in from the inlet port of the cooling block is cooled by passing through the cooling block and the liquid contact part, which have been cooled by thermoelectric module, and then flows out from the outlet port. The absorbed heat and the generated heat are cooled by fan to be dissipated through heat conductive materials like aluminum from the opposite side of the thermoelectric module. (*1)
(*1) The heat absorbed through the heat dissipation fin is exhausted from the fan on heat dissipation side.


Example of use

使用例

 

Model/Specifications

Model OCE-F80LA-D24 OCE-F80LT-D24 OCE-F160LA-D24 OCE-F160LT-D24 OCE-F240LA-D24 OCE-F240LT-D24
Cooling method Fan-cooled Fluid cooling type
Cooling capacity 95W 90W 220W 190W 320W 280W
Heating capacity *1 300W 620W 930W
Rated voltage Fan *2 DC24V ±5%
Peltier
Current consumption 9.0A or less 18.0A or less 27.0A or less
Starting current *3 11.3A 22.0A 32.5A
Working temperature*4 0 to +50℃
Working humidity Max. 80%RH, free from condensation
Liquid temperature *5 Max. +50℃, ice-free
Noise 45dB(A) 49dB(A) 46dB(A)
Max. allowable temp. for Cooling jacket
+80℃
Max. allowable temp. for Dissipation fin base
+80℃
Vibration resistance Vibration frequency 10-55Hz Total amplitude 0.7mm
Cycle 5min X, Y and Z axis 25min each
Conformity to standards Environment RoHS
Circulation fluid Purified water, tap water, etc. Seawater, chemical liquid, etc. Purified water, tap water, etc. Seawater, chemical liquid, etc. Purified water, tap water, etc. Seawater, chemical liquid, etc.
Fluid contact part Aluminum
(SUS304 partially)
Titanium Aluminum
(SUS304 partially)
Titanium Aluminum
(SUS304 partially)
Titanium
Pressure resitance in piping 0.5MPa
Outer diameter of pipe connection port Ø10.5 Ø10 Ø10.5 Ø10 Ø10.5 Ø10
Dimensions (mm)*6 W180×H135×D182 W320×H135×D182 W190×H268×D180
Weight 2.4kg 5.2kg 7.2kg
*1 Nominal value at 30℃ ambient temp. by applying our capacity measurement method by product type
*2 Nominal value when both ambient and circulation liquid temperatures are 30℃
*3 Rated value when the unit runs cooling operation at 30℃ ambient temp. (The value varies depending on temperature. See the table below. )
*4 Value at 30℃ ambient temp. (The value varies depending on temperature. See the table below. )
*5 Pay attention to prevent circulation liquid from freezing.
*6 Terminal board and projection are excluded.

Correlation between temperature and current value

  Ambient temperature 0℃ 15℃ 30℃ 50℃
OCE-F80LA/LT-D24
(incl. 0.25A for fan)
Rated current consumption (A) 11.1 10.1 9.0 8.5
Starting current (A)
12.6 11.9 11.3 10.3
OCE-F160LA/LT-D24
(incl. 0.5A for fan)
Rated current consumption (A) 21.7 19.6 18.0 16.8
Starting current (A)
24.7 23.3 22.0 20.1
OCE-F240LA/LT-D24
(incl. 0.56A for fan)
Rated current consumption (A) 32.0 29.0 27.0 25.0
Starting current (A)
36.6 34.5 32.5 29.6

 


Product lineup

OCE-F80LA/LT-D24

OCE-F80LA-D24

 

Cooling capacity

F80LA:95W F80LT:90W

A complete set of supply

BOXCOOL : 1 unit Instruction manual : 1 copy

F80LA Performance chart

能力特性図

 

F80LT Performance chart

能力特性図

 

F80LA Achieving temp. characteristic chart

到達温度特性図

 

F80LT Achieving temp. characteristic chart

到達温度特性図

 

F80LA Dimensional drawing

外形寸法図

 

F80LT Dimensional drawing

外形寸法図


 

OCE-F160LA/LT-D24

OCE-F160LA/LT-D24

 

Cooling capacity

F160LA:220W F160LT:190W

A complete set of supply

BOXCOOL : 1 unit Instruction manual : 1 copy

F160LA Performance chart

能力特性図

 

F160LT Performance chart

能力特性図

 

F160LA Achieving temp. characteristic chart

到達温度特性図

 

F160LT Achieving temp. characteristic chart

到達温度特性図

 

F160LA Dimensional drawing

外形寸法図

 

F160LT Dimensional drawing

外形寸法図

 

 

OCE-F240LA/LT-D24

OCE-F240LA/LT-D24

 

Cooling capacity

F240LA:320W F240LT:280W

A complete set of supply

BOXCOOL : 1 unit Instruction manual : 1 copy

F240LA Performance chart

能力特性図

 

F240LT Performance chart

能力特性図

 

F240LA Achieving temp. characteristic chart

到達温度特性図

 

F240LT Achieving temp. characteristic chart

到達温度特性図

 

F240LA Dimensional drawing

外形寸法図

 

F240LT Dimensional drawing

外形寸法図

 

System combination

By combination of BOXCOOL and components, various systems having different operation control from continuous operation to precise inversion control can be built.

①Continuous cooling

Combines BOXCOOL with a power supply for continuous running

連続冷却

 

Component name Model
OCE-F80LA-D24
OCE-F80LT-D24
OCE-F160LA-D24
OCE-F160LT-D24
OCE-F240LA-D24
OCE-F240LT-D24
Switched-mode power supply PBA300F-24 PBA600F-24 Contact us for the details
AC wiring ※1 WH-A-M4-2
DC wiring WH-P-M5-2、WH-F-M5-2 WH-P-M5-2 (2 pcs), WH-F-M5-2
*1 For 100VAC power supply

②Simple thermal control system

ON/OFF control is done by a temperature controller using a contact in the power supply.

簡易冷却温調システム

 

Component name Model
OCE-F80LA-D24
OCE-F80LT-D24
OCE-F160LA-D24
OCE-F160LT-D24
OCE-F240LA-D24
OCE-F240LT-D24
Temeprature controller OCE-TC91-8Y1-1C Contact us for the details
Switched-mode power supply PBA300F-24 PBA600F-24
Temperature sensor OCE-TCPT**
AC wiring ※1 WH-A-M4-2
Wiring to temperature controller WH-C2
DC wiring WH-P-M5-2, WH-F-M5-2 WH-P-M5-2 (2 pcs), WH-F-M5-2
*1 For 100VAC power supply

③Precise inversion control system

Highly precise temperature control is achieved by linear voltage controlled switching of cooling and heating using our Temperature Control system designed for BOXCOOL.

精密反転温調システム

 

Component name Model
OCE-F80LA-D24
OCE-F80LT-D24
OCE-F160LA-D24
OCE-F160LT-D24
OCE-F240LA-D24
OCE-F240LT-D24
Temperature control system OCE-TCR24300WL OCE-TCR24600WL Contact us for the details
Temperature sensor OCE-TCPT**
AC wiring *1 WH-A-M4-2
DC wiring WH-P-M4-2, WH-F-M4-2 WH-P-M4-2 (2 pcs),WH-F-M4-2
*1 For 100VAC power supply
 
 

Cautions

・Avoid controlling supply voltage to the fan. Failure to this can be a cause of breakdown of the product.
・Do not use this product in a place where flammable or corrosive gasses, oil fume or any matters that can destroy insulation generate or permeate.
・The site of use should be free from vibration and impact.
・Electrical works required for installation of this product should be done only by professionals or qualified personnel.
・Indoor use only.
・Make sure that the packaging is not damaged on delivery. Any packaging damage can lead to breakdown of the product. Please contact us immediately if any damage is found.