https://duniapermainan.id/https://borobudur.site/https://beritamakan.xyz/http://lesfergusonjr.com/https://www.drafthorsejournal.net/https://ajudanze.us/https://soykb.org/https://www.laoplazahotel.com/https://bidpropamkaltara.com/https://www.inmercociudades.org/https://hanomantoto.vip/https://www.ha-software.com/https://www.demo.mimikakab.go.id/
Forced air cooling type

Forced air cooling type

Forced air cooling type

Forced air cooling type

Powerfully dehumidifies air by forcible air convection using a fan

ODE-F

 

Features

Environment of use Dehumidification method Specifications
Indoor Thermoelectric Energy saving mode Wide range of supply voltages

 

Certificates/Approvals

EU RoHS2 China RoHS CE UL CSA PSE

 

Model/Specifications

Model ODE-F110-AW ODE-F122-AW
Dehumidification capacity*1 10ml/h 22ml/h
Rated voltage Single phase, 100 - 240V AC
Current consumption Dehumidification ON 0.20A (100VAC) 0.15A (240VAC) 0.70A (100VAC) 0.40A (240VAC)
Dehumidification OFF 0.02A (100VAC) 0.03A (240VAC) 0.05A (100VAC) 0.06A (240VAC)
Starting current 2.5A 4.5A
Rated power consumption Dehumidification ON 14W 50W
Dehumidification OFF 2W 5W
Working temperature 0 to +55℃, ice-free
Working humidity Max. 95%RH
Operation mode Continuous/Automatic (Energy-saving)
Setting for automatic operation To run when humidity is 50% or higher and stop when it drops below 50%
Function ・Detection of high temperature at radiation part……When radiation part has reached +80℃
・Detection of thermoelectric module error……… When current value of the thermoelecric module has dropped
・Detection of abnormal working temperature……When operation has stopped outside the working
temperature range (below 0℃ or beyond +60℃)
・Detection of temperature sensor disconnection…… When temperature sensor caused wire disconnection
Error output Contact capacity 24V DC 300mA 1a
Power connection Triplex power cable, 1.3m
Noise 42.5dB(A) 49dB(A)
Conformity to standards EMC Directive EN61000-3-2、EN61000-3-3、EN61000-6-2、EN61000-6-4
Low Voltage Directive EN60335-1、EN60335-2-40
Environment RoHS2
Dimensions (mm) *2 W131×H161.5×D65 W131×H250.5×D65
Weight 1.2kg 1.8kg
*1 Nominal value when ambient temperatures is +30℃ and humidity is 80%RH
*2 Drain pipe, cable and mounting stay are excluded.
  • Supply voltage should be within the specified range with fluctuation not exceeding ±10%.

 


Product lineup

ODE-F110-AW

ODE-F110-AW

 

Dehumidification capacity

10ml/h

A complete set of supply

BOXDRY : 1 unit Drain hose Ø8-Ø11 : 1 pc. 1.5 m long 
Wire harness for alarm output : 1 pc. 0.5 m long Instruction manual : 1 copy
Dehumidification capability of BOXDRY is determined by inner volume of the enclosure to which it is applied. The intersection of the vertical axis and the performance curve shows the dehumifificaiton capability. Use of 2 units doubles the inner volume.

Dehumidification characteristics chart

除湿特性表

 

Performance by internal volume (in cont. run)

除湿能力適用容積表

 

Note : The chart shows correlation of internal humidity and enclosure inner volume under the condition at 100%RH and 30℃ temperature outside the enclosure provided that the enclosure has no vent having a hermetically sealed door which is not opened more than one time a day.

Dimensional drawing

外形寸法図

 

Expanded view of Section A

 

Mounting cutout

パネルカット図

 

Structural drawing

構造図

 

Installation drawing

取付図

 


ODE-F122-AW

ODE-F122-AW

 

Dehumidification capacity

22ml/h

A complete set of supply

BOXDRY : 1 unit Drain hose Ø8-Ø11 : 1 pc. 1.5 m long 
Wire harness for alarm output : 1 pc. 0.5 m long Instruction manual : 1 copy
Dehumidification capability of BOXDRY is determined by inner volume of the enclosure to which it is applied. The intersection of the vertical axis and the performance curve shows the dehumifificaiton capability. Use of 2 units doubles the inner volume.

Dehumidification characteristics chart

除湿特性表

 

Performance by internal volume (in cont. run)

除湿能力適用容積表

 

Dimensional drawing

外形寸法図

 

Expanded view of Section A

 

Mounting cutout

パネルカット図

 

Structural drawing

構造図

 

Installation drawing

取付図

 

Temperature/Relative humidity data recording function

データ記録機能

 

・Enabled data recording of temperature and relative humidity by the integrated sensor (up to 1000 data)
・Enabled analysis of temperature/relative humidity histories by time under environmental conditions of the site

・For data analysis,「use a dedicated software and cable.

Related products

Drain evaporator

 

For eliminating troublesome drain management
 

Cautions

・This product is designed to be installed in an enclosure.
・Make sure that the enclosure is hermetically sealed with no vent.
・Do not use this product in a place where flammable or corrosive gasses or any matters that can destroy insulation generate or permeate.
・The site of use should be free from vibration and impact.
・Electrical works required for installation of this product should be done only by professionals or qualified personnel.
・install BOXDRY perpendicularly within 1 degree angular tolerance.
・Pay attention in attaching the drain hose (accessory). Bent or clogged hose causes trouble in drainage, which may lead to water leak into the enclosure.
・Make sure that the packaging is not damaged on delivery and contact your supplier.Any packaging damage may be a cause of breakdown.