Designed for Non-filter oil mist collector OMC-N2 series Drastically cuts maintenance works!
EU RoHS | China RoHS | CE | UL | CSA | PSE |
Model | OMC-ATW-N21 | OMC-ATW-N22 | |
Rated voltage*1 | Single phase, 200VAC 50/60Hz | Single phase, 220VAC 50/60Hz | |
Rated power consumption | 14W | ||
Applicable models | OMC-N2 series | ||
Operation mode | AUTO(Factory setting: Spraying for 20 seconds every three hours)MANUAL(Continuous spraying) | ||
Recommended spraying time | 20 - 40 seconds (Factory setting : 20 sec.) | ||
Standby time | 0 to 30 hours(Factory setting : 3 hours) | ||
Spraying amount*2 | 0.6mL/s (at 1m lift height) | ||
Power source for spraying | Compressed air | ||
Required supply air pressure | 0.3 - 0.8MPa | ||
Max. lift height | 2m | ||
Washing liquid | Water (0 to +40℃, ice-free) | ||
Power cable | 3m | ||
Working temperature | 0 to +40℃, ice-free | ||
Working humidity | 35 - 85%RH, free from condensation | ||
Conformity to standards | Environmental standard | RoHS |